A766 Aramid Insulation Paper
UL Certification No.: E509207
Aratech® A766 is a high-temperature, calendered aramid insulation paper designed for Class H and C systems (200 °C). The calendered structure provides superior density, dimensional stability, and uniform electrical properties. With strong resistance to heat, flames, and chemicals, it delivers consistent performance in even the most demanding applications,  making it an ideal choice for virtually every known electrical sheet insulation application. A766 is non-toxic and eco-friendly, and passed UL94 V-0 and VTM-0 burning tests.
It can be supplied in slit rolls (depending on the material thickness) or in rolls (≤ 2000mm)
Request Your Free QuoteWorld-Class Aramid Insulation
Electrical Insulation Aramid Paper Solutions
As electrical systems become more powerful and compact, the demands on insulation intensify. We are the manufacturing partner for the future, producing aramid paper with the enhanced thermal and dielectric properties required for tomorrow's technology. Build safer, more reliable, and more competitive products with our forward-thinking insulation solutions.

Surface microstructure

Surface microstructure

Surface microstructure

High-Strength Aramid Paper for Demanding Insulation Applications.
Aratech® A766 Core Performance Features
 The high-pressure calendering process creates a smooth, non-porous surface and a highly uniform internal structure, resulting in exceptional performance.
Where It Works
Main Application Areas
A766 is suitable for a full range of applications requiring sheet-type electrical insulation materials, offering strong overload resistance. It can be used in traction transformers, mining transformers, explosion-proof transformers, power transformers, reactors, and rectifiers for inter-turn, inter-layer, and end insulation. It is also applicable to traction motors, hydroelectric motors, wind power motors, mining and metallurgical motors, new energy vehicle drive motors, as well as generators operating under demanding electrical and thermal conditions



Technical Data Snapshot
| Items | Unit | TypicalValue | TestMethods | |||||||
| 
 NominalThickness 
 | 
mm | 0.05 | 0.08 | 0.13 | 0.18 | 0.22 | 0.25 | 0.3 | 0.38 | / | 
| mil | 2 | 3 | 5 | 7 | 8.5 | 10 | 12 | 15 | / | |
| TypicalThickness | mm | 0.059 | 0.081 | 0.134 | 0.183 | 0.225 | 0.268 | 0.323 | 0.404 | GB/T451.3 | 
| BasisWeight | g/m² | 41 | 64 | 117 | 168 | 216 | 257 | 311 | 388 | GB/T451.2 | 
| Density | g/m³ | 0.7 | 0.79 | 0.87 | 0.92 | 0.96 | 0.96 | 0.96 | 0.96 | GB/T451.3 | 
| DielectricStrength | kV/mm | 17 | 21 | 23 | 25 | 28 | 24 | 22 | 22 | GB/T1408.1 | 
| DielectricConstant | — | 1.6 | 1.6 | 2.3 | 2.5 | 2.6 | 2.8 | 2.9 | 2.9 | 
 GB/T1409 
 | 
| Dielectric Loss Factor | X 10⁻³ | 4 | 5 | 6 | 6 | 6 | 6 | 8 | 8 | |
| 
 TensileStrength 
 | 
MD (N/cm) | 38 | 68 | 138 | 225 | 280 | 320 | 360 | 446 | 
 GB/T12914 
 | 
| CD (N/cm) | 19 | 39 | 69 | 115 | 140 | 165 | 183 | 230 | ||
| 
 Elongation 
 | 
MD (%) | 6 | 7.5 | 11 | 11 | 12 | 13 | 10 | 11 | 
 GB/T12914 
 | 
| CD (%) | 5 | 6.5 | 9 | 9 | 9 | 10 | 7 | 9 | ||
| 
 ElmendorfTearStr. 
 | 
MD.(N) | 0.7 | 0.95 | 2 | 3.1 | 3.6 | 4.5 | 5.7 | 7.5 | 
 GB/T455 
 | 
| CD (N) | 1.3 | 1.7 | 3.5 | 5.3 | 6.6 | 8.5 | 10.7 | 14 | ||
Global Leader in Paper-Based Electrical Insulation
Why Choose Us
Partnering with Times Huaxian means more than sourcing reliable materials—it means securing a future-ready supply chain and accessing flexible solutions. We combine industrial scale with scientific rigor to support global distributors, OEMs, and service providers in building reliable electrical futures.